spacer






  with Electric Gearbox Operator

Gearbox Operator Dimensions & Data


Note: Door panel thickness is based on 20 pound per square foot load with L/120 deflection.

EPD Electric Operator Details & Dimensions
Door Size
Door
Clearances
Hinge
Maximum
Motor
Guide
Operator
Panel
Offset
Time
Horse
Track
Size
Thickness
To Open
Power
Type
Width
x
Height
A
B
C
D
8'-0"
8' to 12'
2"
15"
2'-7"
32"
17"
6"
5 Sec.
1/2 HP
Channel
ED-00
9'-0"
8' to 12'
2"
15"
2'-10"
32"
17"
6"
5 Sec.
1/2 HP
Channel
ED-00
10'-0"
8' to 12'
2"
15"
3'-1"
32"
17"
6"
5 Sec.
1/2 HP
Channel
ED-00
10'-0"
13' to 14'
2"
17"
3'-1"
36"
17"
6"
7 Sec.
3/4 HP
Channel
ED-1&2
11'-0"
12' to 14'
2"
17"
3'-4"
36"
17"
6"
7 Sec.
3/4 HP
Channel
ED-1&2
12'-0"
12' to 14'
2"
17"
3'-7"
36"
17"
6"
7 Sec.
3/4 HP
Channel
ED-1&2
13'-0"
12' to 14'
2"
17"
3'-10"
36"
17"
6"
7 Sec.
3/4 HP
Channel
ED-1&2
14'-0"
12' to 14'
2"
17"
4'-1"
36"
17"
6"
7 Sec.
3/4 HP
Channel
ED-1&2
14'-0"
14' to 16'
3"
18"
4'-3"
42"
17"
8"
9 Sec.
1 HP
S-Beam
ED-3&4
15'-0"
11' to 16'
3"
18"
4'-6"
42"
17"
8"
9 Sec.
1 HP
S-Beam
ED-3&4
16'-0"
11' to 16'
3"
18"
4'-9"
42"
17"
8"
9 Sec.
1 HP
S-Beam
ED-3&4
17'-0"
11' to 16'
3"
18"
5'-0"
42"
17"
8"
9 Sec.
1 HP
S-Beam
ED-3&4
18'-0"
11' to 16'
3"
18"
5'-3"
42"
17"
8"
9 Sec.
1 HP
S-Beam
ED-3&4

For smaller or larger door sizes, consult the EPD factory at (800) 346-5760.